The No Wake-up watches for long periods of morning inactivity while filtering out short activity events. It triggers an alert when the inactivity pattern meets the criteria defined in the monitor parameters. It is based on Active Minute detection. Dashboard users can create monitors and receive No wake-up alerts.
Configuration
- Select a Profile
- Go to the Settings panel, and scroll down to the Monitors section
- Scroll down to the Monitors section
- Click on the add button
- Pick No wake up as monitor type
No wake-up monitors have the following parameters:
| Parameters | Description | Available range | Example |
|---|---|---|---|
| Start time of expected wake-up window | Local (place timezone) time of the day at which the monitor will start looking for activity periods longer than the suppress interruptions threshold. | 00:00 - 11:59 | 4:00AM |
| End time of expected wake-up window | Local (place timezone) time of the day at which the alert is triggered if no activity period longer than the suppress interruptions threshold has been detected | 00:00 - 11:59 | 7:00AM |
| Suppress interruptions threshold | Maximum duration of the activity periods the monitor will discard. Shorter activities won’t be considered as a wake-up (to filter out bathroom trips, turning over in bed) | 1 - 10 | 3 minutes |
ℹ️ Currently, the observation window applies every day of the week. Different schedules cannot yet be configured for different days.
Example: monitoring wake-up
- Start time of expected wake-up window : 4:00 AM
- End time of expected wake-up window: 7:00 AM
- Suppress interruptions threshold : 3 minutes
John Doe usually wakes up and moves around the house between early morning and late morning. His caregiver wants to ensure he started his day like usual. If John is not sufficiently active between 4:00AM and 7:00AM, the monitor will trigger an alert around 7:10AM. If John only turned around during his sleep, or did a quick trip to the bathroom, it won’t pass the suppress interruptions threshold and therefore won’t count as a proper wake-up, so the alert will be triggered.
Best practices
- Ensure that Active Minute coverage is good before setting up a monitor
- Choose an expected wake-up window to cover only the expected waking period, and not the full sleep period (ex: 9PM - 6AM)
- Focus on normal sleep routines and adapt to the person's routine wake-up time. If the person’s sleep routine is erratic, look into more generic monitors like the No activity monitor
Triggers
No Activity Alerts are presented in the Alert panel, accessible from the left navigation bar. There, users can view the alert detail and resolve it.
- Latency: inactivity periods are evaluated every 10 minutes. It means that at most, the alert will be received 10 minutes after inactivity period reaches the duration threshold.
- Once created, a monitor will be active by default. You can pause a monitor anytime you want, which will prevent it from triggering alerts.